Diseño de encofrados verticales: dimensionado y tiempos mínimos de desencofrado
Ver ítem

No hay ficheros asociados a este ítem.

                       
Ver texto completo
           
Compartir
Exportar citas
Exportar a Mendeley
Estadísticas
En
Memoria Investigaciones en Ingeniería; Núm. 13 (2015); 7-16
Editor
Universidad de Montevideo
Notas
The design of vertical formworks depends on the maximum lateral pressure exerted by fresh concrete for dimensioning the panels and the time needed for use it. In this work, the experimental models to predict the maximum lateral pressure exerted by the self-compacting concrete (SCC) on vertical formwork are described. On the other hand, the minimum demoulding times proposed by different normatives and different researches in the literature are described. Finally, a formwork removal method based on the ASTM 403 standard is developed and experimental tests were carried out in Uruguay for the validation of the presented method.

El diseño de encofrados verticales depende de la predicción de la máxima presión lateral ejercida por el hormigón en estado fresco para el dimensionado de los paneles y del tiempo necesario de utilización de los mismos. En este trabajo se describen los modelos experimentales descritos en la bibliografía para predecir la máxima presión lateral ejercida por el hormigón autocompactante (HAC) en encofrados verticales y los tiempos de desencofrados propuestos por las diferentes normativas y los distintos autores en la literatura. Finalmente, se presenta un método de desencofrado desarrollado en base a la norma ASTM 1074 y la campaña experimental realizada en una de las hormigoneras más grandes de Uruguay para la validación de dicho método.