Memoria Investigaciones en Ingeniería; Núm. 8 (2010); 81-89
Editor
Universidad de Montevideo
Notas
The design of vertical formwork is dependent on the lateral pressure predicted to act on the form face. Experimental research into the construction of 11 columns was carried out with the objective of verifying and comparing the adequacy of different theories. Pressure was measured in a direct form using pressure sensors, which permits verify the maximum lateral pressure. The results shown that the model prediction match with the hydrostatic distribution, being in general conservative, therefore much more research is needed with the objective of determined a model to predict in a better form the lateral pressure realized by fresh concrete, at high placement rates.

El diseño de los encofrados verticales depende de la predicción en la presión lateral contra la superficie del mismo. Un trabajo experimental en la construcción de 11 columnas de hormigón se ha llevado a cabo con el objetivo de verificar la adecuación de diferentes modelos. La presión ha sido medida en forma directa a partir de la colocación de sensores de presión sobre un panel del encofrado, lo que permite verificar la máxima presión lateral propuesta por los diferentes modelos. Los resultados reflejan que la predicción de los modelos coincide con la distribución hidrostática de un líquido con la misma densidad que el hormigón, lo cual es generalmente conservativo. Por lo tanto mucho más trabajo es necesario para poder realizar un modelo que sea capaz de predecir la máxima presión lateral a altas velocidades de llenado.