Vertical formwork design: Dimensioning and Minimum Demoulding Times

Diseño de encofrados verticales: dimensionado y tiempos mínimos de desencofrado

dc.creatorTeixeira, Sofía
dc.creatorSantilli, Adrián
dc.creatorPuente, Iñigo
dc.date2015-11-02
dc.identifierhttp://revistas.um.edu.uy/index.php/ingenieria/article/view/338
dc.descriptionThe design of vertical formworks depends on the maximum lateral pressure exerted by fresh concrete for dimensioning the panels and the time needed for use it. In this work, the experimental models to predict the maximum lateral pressure exerted by the self-compacting concrete (SCC) on vertical formwork are described. On the other hand, the minimum demoulding times proposed by different normatives and different researches in the literature are described. Finally, a formwork removal method based on the ASTM 403 standard is developed and experimental tests were carried out in Uruguay for the validation of the presented method.en-US
dc.descriptionEl diseño de encofrados verticales depende de la predicción de la máxima presión lateral ejercida por el hormigón en estado fresco para el dimensionado de los paneles y del tiempo necesario de utilización de los mismos. En este trabajo se describen los modelos experimentales descritos en la bibliografía para predecir la máxima presión lateral ejercida por el hormigón autocompactante (HAC) en encofrados verticales y los tiempos de desencofrados propuestos por las diferentes normativas y los distintos autores en la literatura. Finalmente, se presenta un método de desencofrado desarrollado en base a la norma ASTM 1074 y la campaña experimental realizada en una de las hormigoneras más grandes de Uruguay para la validación de dicho método.es-ES
dc.formatapplication/pdf
dc.languagespa
dc.publisherUniversidad de Montevideoes-ES
dc.relationhttp://revistas.um.edu.uy/index.php/ingenieria/article/view/338/408
dc.rightsDerechos de autor 2019 Sofía Teixeira, Adrián Santilli, Iñigo Puentees-ES
dc.rightshttp://creativecommons.org/licenses/by/4.0es-ES
dc.sourceMemoria Investigaciones en Ingeniería; No. 13 (2015); 7-16en-US
dc.sourceMemoria Investigaciones en Ingeniería; Núm. 13 (2015); 7-16es-ES
dc.sourceMemoria Investigaciones en Ingenieria; n. 13 (2015); 7-16pt-BR
dc.source2301-1106
dc.source2301-1092
dc.subjectHormigón autocompactante (HAC)es-ES
dc.subjectEncofrados verticaleses-ES
dc.subjectPresión laterales-ES
dc.subjectTiempos mínimos de desencofradoes-ES
dc.subjectSelf-compacting concrete (SCC)en-US
dc.subjectVertical formworken-US
dc.subjectLateral pressureen-US
dc.subjectMinimum demoulding timesen-US
dc.titleVertical formwork design: Dimensioning and Minimum Demoulding Timesen-US
dc.titleDiseño de encofrados verticales: dimensionado y tiempos mínimos de desencofradoes-ES
dc.typeinfo:eu-repo/semantics/article
dc.typeinfo:eu-repo/semantics/publishedVersion
dc.typePeer reviewed articlesen-US
dc.typeArtículos evaluados por pareses-ES
dc.typeArtigos revistos por parespt-BR